Subversion Repositories HomeAutomation

Rev

Rev 1907 | Rev 1921 | Go to most recent revision | Show entire file | Regard whitespace | Details | Blame | Last modification | View Log | SVN | RSS feed

Rev 1907 Rev 1920
Line 1326... Line 1326...
1326
        <variable name="Row7" type="uint" start_bit="48" bit_length="8" unit="" description=""/>
1326
        <variable name="Row7" type="uint" start_bit="48" bit_length="8" unit="" description=""/>
1327
        <variable name="Row8" type="uint" start_bit="56" bit_length="8" unit="" description=""/>
1327
        <variable name="Row8" type="uint" start_bit="56" bit_length="8" unit="" description=""/>
1328
      </variables>
1328
      </variables>
1329
    </command>
1329
    </command>
1330
 
1330
 
-
 
1331
    <command id="128" name="Data start" type="specific" module="rfTransceiver" description="Data protocol encoding">
-
 
1332
      <variables>
-
 
1333
        <variable name="Channel" type="uint" start_bit="0" bit_length="4" unit="" description="Channel of received or transmitted data"/>
-
 
1334
        <variable name="Protocol" type="enum" start_bit="8" bit_length="8" unit="" description="Protocol">
-
 
1335
          <value id="0" name="RC5"/>
-
 
1336
          <value id="1" name="RC6"/>
-
 
1337
          <value id="2" name="RCMM"/>
-
 
1338
          <value id="3" name="SIRC"/>
-
 
1339
          <value id="4" name="Sharp"/>
-
 
1340
          <value id="5" name="NEC"/>
-
 
1341
          <value id="6" name="Samsung"/>
-
 
1342
          <value id="7" name="Marantz"/>
-
 
1343
          <value id="8" name="Panasonic"/>
-
 
1344
          <value id="9" name="Sky"/>
-
 
1345
          <value id="10" name="Nexa2"/>
-
 
1346
          <value id="11" name="Nexa"/>
-
 
1347
          <value id="255" name="Unknown"/>
-
 
1348
        </variable>
-
 
1349
        <variable name="Data" type="uint" start_bit="16" bit_length="48" unit="" description="Protocol unique ID"/>
-
 
1350
      </variables>
-
 
1351
    </command>
-
 
1352
    <command id="129" name="Data stop" type="specific" module="rfTransceiver" description="Data protocol encoding">
-
 
1353
      <variables>
-
 
1354
        <variable name="Channel" type="uint" start_bit="0" bit_length="4" unit="" description="Channel of received or transmitted data"/>
-
 
1355
        <variable name="Protocol" type="enum" start_bit="8" bit_length="8" unit="" description="Protocol">
-
 
1356
          <value id="0" name="RC5"/>
-
 
1357
          <value id="1" name="RC6"/>
-
 
1358
          <value id="2" name="RCMM"/>
-
 
1359
          <value id="3" name="SIRC"/>
-
 
1360
          <value id="4" name="Sharp"/>
-
 
1361
          <value id="5" name="NEC"/>
-
 
1362
          <value id="6" name="Samsung"/>
-
 
1363
          <value id="7" name="Marantz"/>
-
 
1364
          <value id="8" name="Panasonic"/>
-
 
1365
          <value id="9" name="Sky"/>
-
 
1366
          <value id="10" name="Nexa2"/>
-
 
1367
          <value id="11" name="Nexa"/>
-
 
1368
          <value id="255" name="Unknown"/>
-
 
1369
        </variable>
-
 
1370
        <variable name="Data" type="uint" start_bit="16" bit_length="48" unit="" description="Protocol unique ID"/>
-
 
1371
      </variables>
-
 
1372
    </command>
-
 
1373
    <command id="130" name="Data burst" type="specific" module="rfTransceiver" description="Data protocol encoding">
-
 
1374
      <variables>
-
 
1375
        <variable name="Channel" type="uint" start_bit="0" bit_length="4" unit="" description="Channel of received or transmitted data"/>
-
 
1376
        <variable name="Protocol" type="enum" start_bit="8" bit_length="8" unit="" description="Protocol">
-
 
1377
          <value id="0" name="RC5"/>
-
 
1378
          <value id="1" name="RC6"/>
-
 
1379
          <value id="2" name="RCMM"/>
-
 
1380
          <value id="3" name="SIRC"/>
-
 
1381
          <value id="4" name="Sharp"/>
-
 
1382
          <value id="5" name="NEC"/>
-
 
1383
          <value id="6" name="Samsung"/>
-
 
1384
          <value id="7" name="Marantz"/>
-
 
1385
          <value id="8" name="Panasonic"/>
-
 
1386
          <value id="9" name="Sky"/>
-
 
1387
          <value id="10" name="Nexa2"/>
-
 
1388
          <value id="11" name="Nexa"/>
-
 
1389
          <value id="255" name="Unknown"/>
-
 
1390
        </variable>
-
 
1391
        <variable name="Data" type="uint" start_bit="16" bit_length="48" unit="" description="Protocol unique ID"/>
-
 
1392
      </variables>
-
 
1393
    </command>
1331
 
1394
 
1332
  </commands>
1395
  </commands>
1333
 
1396
 
1334
 
1397
 
1335
  <modules>
1398
  <modules>