Subversion Repositories HomeAutomation

Rev

Go to most recent revision | Show changed files | Details | Compare with Previous | Blame | SVN | RSS feed

Filtering Options

Rev Age Author Path Log message Diff
2229 5118 d 18 h linlun /trunk/ Added configuration message for ultrasonic module in data.xml  
2225 5153 d 20 h linlun /trunk/ Added ultrasonic module and distance command to data.xml  
2186 5191 d 5 h arune /trunk/Configuration/ Changed setvolume function unit to liters from milliliters  
2183 5192 d 2 h arune /trunk/ Added support for setting volume and report interval over CAN, untested  
2166 5197 d 15 h arune /trunk/ Added physical command "Flow"  
2040 5239 d 17 h arune /trunk/ Changed bit length of variable IRdata of command physical IR, also updated depending modules sns_rfTransceive, sns_irReceive, sns_irTransmit and sns_irTransceive
If you update data.xml for Atom then you must also update embedded software modules (you nodes software)
 
2032 5244 d 14 h pengi /trunk/ First version of RFID reader, and it seems to work-ish!  
2025 5260 d 16 h arune /trunk/Configuration/ Removed unused module definitions, added empty lines to show where there are free moduled ids  
2021 5263 d 17 h arune /trunk/ Added module sns_heatPower to data.xml and modulid.h  
1996 5277 d 18 h arune /trunk/ Changed commands used of rfTransceive to the old physical command instead of new specific  
1982 5282 d 7 h linlun /trunk/ Added sns_qtouch to data.xml and moduleid.h  
1942 5318 d 23 h myhrman /trunk/Configuration/ Added specific pronto response codes when channel is busy, or when modfreq is locked to another value by other channel.  
1931 5336 d 18 h arune /trunk/ Added protocol Viking to configuration, no implementation done
Added support for burst protocols in rfTransceiver module
Should not break anything
 
1922 5369 d 17 h arune /trunk/ Added sns_rfTransceive, light version of IR-Transceive and aimed for RF rx tx. Only RX implemented.
Configuration updated with fixes to sns_rfTransceive
IR/RF-protocols fix for nexa timeout
 
1921 5372 d 2 h arune /trunk/ Fixed spaces in data.xml names  
1920 5372 d 2 h arune /trunk/ Added protocol specific for rf transceiver  
1907 5384 d 17 h arune /trunk/ Added module rftransceiver in configuration  
1904 5393 d 17 h arune /trunk/ Added skeleton for nexa1  
1897 5396 d 2 h runge /trunk/ Changed name of hwPWM id to channel to be the same as the input and the dimmer  
1870 5416 d 21 h linlun /trunk/ Added DHT11 temperature and humidity sensor support  

Show All