2201 5137 d 18 h arune /trunk/EmbeddedSoftware/AVR/application/ Removed depricated ir applications  
2200 5137 d 18 h arune /trunk/EmbeddedSoftware/AVR/ Added RF protocol Viking temperature sensor receive parser
Bugfix in Nexa2 implementation
 
2199 5138 d 1 h arune /trunk/EmbeddedSoftware/AVR/ Implementation of continuous mode for ir/rf pulse receiver done and working for Nexa2
Updated irReceiver and irTransceiver modules to support new driver
 
2198 5138 d 4 h arune /trunk/EmbeddedSoftware/AVR/ Work done on rf continuous mode, buffer index still not implemented
Bug fix in protocol for Nexa2 and Nexa1 (start bit checks)
 
2194 5140 d 2 h arune /trunk/EmbeddedSoftware/AVR/module/sns_irTransceive/ Added IR-protocol defines to config.inc.template  
2185 5147 d 5 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Funtion for setting volume over CAN updated after testing, resulted in some other fixes around converting values to send on CAN  
2184 5148 d 2 h arune /trunk/EmbeddedSoftware/AVR/avr-lib/drivers/ Added compiled moduleid.h forgot in last commit
Minor spelling fix in onewire.h
 
2183 5148 d 2 h arune /trunk/ Added support for setting volume and report interval over CAN, untested  
2178 5151 d 17 h arune /trunk/EmbeddedSoftware/AVR/module/sns_Serial/ Initialized filter in case eeprom fails  
2177 5151 d 17 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Added support for eeprom, minor rework of counters  
2176 5151 d 23 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Reverted modulo optimization, not true  
2175 5152 d 2 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Optimization of modulo operations according wikipedia, also minor comment cleanup  
2174 5152 d 16 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Bug fix for previous commit, forgot to use defined constant in code  
2173 5152 d 16 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Minor fixes and tweaks  
2172 5152 d 16 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Minor fixes  
2168 5152 d 19 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Probably solved issue with 32 sample avarage being high from start  
2167 5153 d 15 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Added module for measuring water flow on flow meter with gearwheel  
2166 5153 d 15 h arune /trunk/ Added physical command "Flow"  
2163 5154 d 19 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Added support for meters with 100 pulses per kWh, untested  
2151 5164 d 17 h kribba /trunk/EmbeddedSoftware/AVR/standalone/Can2Serial/ Successfully tested Can2Serial at 1M Baud, changing to default
remember to update atom.conf to make it work
 

Show All