2194 5151 d 11 h arune /trunk/EmbeddedSoftware/AVR/module/sns_irTransceive/ Added IR-protocol defines to config.inc.template  
2185 5158 d 14 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Funtion for setting volume over CAN updated after testing, resulted in some other fixes around converting values to send on CAN  
2183 5159 d 10 h arune /trunk/ Added support for setting volume and report interval over CAN, untested  
2178 5163 d 2 h arune /trunk/EmbeddedSoftware/AVR/module/sns_Serial/ Initialized filter in case eeprom fails  
2177 5163 d 2 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Added support for eeprom, minor rework of counters  
2176 5163 d 8 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Reverted modulo optimization, not true  
2175 5163 d 10 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Optimization of modulo operations according wikipedia, also minor comment cleanup  
2174 5164 d 1 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Bug fix for previous commit, forgot to use defined constant in code  
2173 5164 d 1 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Minor fixes and tweaks  
2172 5164 d 1 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Minor fixes  
2168 5164 d 4 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Probably solved issue with 32 sample avarage being high from start  
2167 5164 d 23 h arune /trunk/EmbeddedSoftware/AVR/module/sns_water/ Added module for measuring water flow on flow meter with gearwheel  
2163 5166 d 4 h arune /trunk/EmbeddedSoftware/AVR/module/sns_power/ Added support for meters with 100 pulses per kWh, untested  
2135 5187 d 8 h linlun /trunk/EmbeddedSoftware/AVR/module/act_hd44780/ Added code for auto backlight  
2134 5187 d 8 h arune /trunk/EmbeddedSoftware/AVR/module/sns_BusVoltage/ Added busvoltage resistor values as config parameters and let config.inc.template have default values for both corecard and coremodule  
2121 5188 d 12 h linlun /trunk/EmbeddedSoftware/AVR/module/sns_rfTransceive/ Changed config.inc.template in rfTranseiver to only support Nexa protocols  
2120 5188 d 12 h linlun /trunk/EmbeddedSoftware/AVR/ Moved so that you can configure which protocols to support for irRecieve into config.inc.template  
2115 5190 d 6 h linlun /trunk/EmbeddedSoftware/AVR/module/act_hwPWM/ Changed name on all fade and demo static variables, they where colliding with variables in dimmer230  
2108 5192 d 2 h linlun /trunk/EmbeddedSoftware/AVR/module/act_hwPWM/ hwPWM: Added more comments in try to make kribba happy, but to fully understand the datascheet is still needed  
2100 5193 d 11 h linlun /trunk/EmbeddedSoftware/AVR/module/act_hwPWM/ Fixed LED compensation function  