| 2 | function PID(type, name, id) |
||
| 3 | { |
||
| 4 | this.CanService(type, name, id); |
||
| 5 | this.myLastValue = new Array(); |
||
| 6 | this.registerEventCallback("online", function(args) { _PID_Online(args); }); |
||
| 7 | } |
||
| 8 | |||
| 9 | function _PID_Online(data) { |
||
| 10 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_SENSOR"); |
||
| 11 | sendMessage(canMessage); |
||
| 12 | canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_ACTUATOR"); |
||
| 13 | sendMessage(canMessage); |
||
| 14 | canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_PARAMETER"); |
||
| 15 | sendMessage(canMessage); |
||
| 16 | canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "Report_Interval"); |
||
| 17 | sendMessage(canMessage); |
||
| 18 | } |
||
| 19 | |||
| 20 | extend(PID, CanService); |
||
| 21 | |||
| 22 | PID.prototype.myReportInterval = null; |
||
| 23 | |||
| 24 | PID.prototype.sensorModuleType = null; |
||
| 25 | PID.prototype.sensorModuleId = null; |
||
| 26 | PID.prototype.sensorId = null; |
||
| 27 | |||
| 28 | PID.prototype.actuatorModuleType = null; |
||
| 29 | PID.prototype.actuatorModuleId = null; |
||
| 30 | PID.prototype.actuatorId = null; |
||
| 31 | |||
| 32 | PID.prototype.K_P= null; |
||
| 33 | PID.prototype.K_I= null; |
||
| 34 | PID.prototype.K_D= null; |
||
| 35 | PID.prototype.TimeUnit= null; |
||
| 36 | PID.prototype.RegulatorTime = null; |
||
| 37 | |||
| 38 | PID.prototype.Measurment = null; |
||
| 39 | PID.prototype.Reference = null; |
||
| 40 | PID.prototype.PWM = null; |
||
| 41 | PID.prototype.Sum = null; |
||
| 42 | |||
| 43 | PID.prototype.canMessageHandler = function(canMessage) |
||
| 44 | { |
||
| 45 | if (canMessage.getDirectionFlag() == "From_Owner") |
||
| 46 | { |
||
| 47 | switch (canMessage.getCommandName()) |
||
| 48 | { |
||
| 49 | case "DEBUG": |
||
| 50 | //<variable name="P_term" type="uint" start_bit="0" bit_length="16" unit="" description=""/> |
||
| 51 | //<variable name="I_term" type="uint" start_bit="16" bit_length="16" unit="" description=""/> |
||
| 52 | //<variable name="D_term" type="uint" start_bit="32" bit_length="16" unit="" description=""/> |
||
| 53 | //<variable name="Sum" type="uint" start_bit="48" bit_length="16" unit="" description=""/> |
||
| 54 | //this.myLastValue[canMessage.getData("Id")] = canMessage.getData("Value"); |
||
| 55 | //this.callEvent("newValue", canMessage.getData("Id")); |
||
| 56 | break; |
||
| 57 | case "CONFIG_SENSOR": |
||
| 58 | this.sensorModuleType= canMessage.getData("sensorModuleType"); |
||
| 59 | this.sensorModuleId= canMessage.getData("sensorModuleId"); |
||
| 60 | this.sensorId= canMessage.getData("sensorId"); |
||
| 1380 | linlun | 61 | log("conf_sensor: " + this.sensorModuleType + " " + this.sensorModuleId + " " + this.sensorId + "\n"); |
| 1374 | linlun | 62 | //this.callEvent("newValue", canMessage.getData("Id")); |
| 63 | break; |
||
| 64 | case "CONFIG_ACTUATOR": |
||
| 65 | this.actuatorModuleType= canMessage.getData("actuatorModuleType"); |
||
| 66 | this.actuatorModuleId= canMessage.getData("actuatorModuleId"); |
||
| 67 | this.actuatorId= canMessage.getData("actuatorId"); |
||
| 68 | //this.callEvent("newValue", canMessage.getData("Id")); |
||
| 1380 | linlun | 69 | log("conf_act: " + this.actuatorModuleType + " " + this.actuatorModuleId + " " + this.actuatorId + "\n"); |
| 1374 | linlun | 70 | |
| 71 | break; |
||
| 72 | case "CONFIG_PARAMETER": |
||
| 73 | this.K_P= canMessage.getData("K_P"); |
||
| 74 | this.K_I= canMessage.getData("K_I"); |
||
| 75 | this.K_D= canMessage.getData("K_D"); |
||
| 76 | this.TimeUnit= canMessage.getData("TimeUnit"); |
||
| 77 | this.RegulatorTime= canMessage.getData("RegulatorTime"); |
||
| 1380 | linlun | 78 | log("conf_param: " + this.K_P + " " + this.K_I + " " + this.K_D + " " + this.RegulatorTime + " " + this.TimeUnit + "\n"); |
| 1374 | linlun | 79 | //this.callEvent("newValue", canMessage.getData("Id")); |
| 80 | break; |
||
| 81 | case "PID_STATUS": |
||
| 82 | this.Measurment= canMessage.getData("Measurment"); |
||
| 83 | this.Reference= canMessage.getData("Reference"); |
||
| 84 | this.PWM= canMessage.getData("PWM"); |
||
| 85 | this.Sum= canMessage.getData("Sum"); |
||
| 1380 | linlun | 86 | log("PID status: mea:" + this.Measurment + " ref:" + this.Reference + " pwm:" + this.PWM/100 + " sum:" + this.Sum + "\n"); |
| 1374 | linlun | 87 | //this.callEvent("newValue", canMessage.getData("Id")); |
| 88 | break; |
||
| 89 | case "Temperature_Celsius": |
||
| 90 | this.Reference= canMessage.getData("Value"); |
||
| 1380 | linlun | 91 | log("PID status: ref:" + this.Reference + "\n"); |
| 1374 | linlun | 92 | //this.callEvent("newValue", canMessage.getData("Id")); |
| 93 | break; |
||
| 94 | case "Report_Interval": |
||
| 95 | this.myReportInterval = canMessage.getData("Time"); |
||
| 96 | break; |
||
| 97 | } |
||
| 98 | } |
||
| 99 | this.CanService.prototype.canMessageHandler.call(this, canMessage); |
||
| 100 | } |
||
| 101 | |||
| 102 | PID.prototype.setValue = function(temperature) |
||
| 103 | { |
||
| 1380 | linlun | 104 | log ("Called SetValue: "+temperature+"\n"); |
| 1374 | linlun | 105 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "Temperature_Celsius"); |
| 1380 | linlun | 106 | canMessage.setData("Value", ""+temperature); |
| 1374 | linlun | 107 | canMessage.setData("SensorId", 0); |
| 1380 | linlun | 108 | log ("> "+canMessage.toString()+"\n"); |
| 1374 | linlun | 109 | sendMessage(canMessage); |
| 1380 | linlun | 110 | |
| 111 | |||
| 1374 | linlun | 112 | } |
| 113 | |||
| 1380 | linlun | 114 | PID.prototype.getConfiguration = function() |
| 115 | { |
||
| 116 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_SENSOR"); |
||
| 117 | sendMessage(canMessage); |
||
| 118 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_ACTUATOR"); |
||
| 119 | sendMessage(canMessage); |
||
| 120 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_PARAMETER"); |
||
| 121 | sendMessage(canMessage); |
||
| 122 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "Report_Interval"); |
||
| 123 | sendMessage(canMessage); |
||
| 124 | } |
||
| 1374 | linlun | 125 | |
| 1380 | linlun | 126 | PID.prototype.setParameters = function(KP,KI,KD,Time,Unit) |
| 127 | { |
||
| 128 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "CONFIG_PARAMETER"); |
||
| 129 | canMessage.setData("K_P", ""+KP); |
||
| 130 | canMessage.setData("K_I", ""+KI); |
||
| 131 | canMessage.setData("K_D", ""+KD); |
||
| 132 | canMessage.setData("RegulatorTime", ""+Time); |
||
| 133 | canMessage.setData("TimeUnit", ""+Unit); |
||
| 134 | //log ("> "+canMessage.toString()+"\n"); |
||
| 135 | sendMessage(canMessage); |
||
| 136 | } |
||
| 137 | |||
| 138 | |||
| 1374 | linlun | 139 | PID.prototype.setReportInterval = function(time) |
| 140 | { |
||
| 141 | var canMessage = new CanMessage("act", "To_Owner", this.myName, this.myId, "Report_Interval"); |
||
| 142 | canMessage.setData("Time", time); |
||
| 143 | sendMessage(canMessage); |
||
| 144 | } |
||
| 145 | |||
| 146 | PID.prototype.getReportInterval = function(time) |
||
| 147 | { |
||
| 148 | |||
| 149 | } |