Subversion Repositories HomeAutomation

Rev

Rev 1543 | Blame | Compare with Previous | Last modification | View Log | SVN | RSS feed

## Section sns_inputAnalog -- Do not edit this line

#Uncomment the line below if you want to use EEPROM with this module, dont forget to also uncomment the line in sources.list
sns_inputAnalog_USEEEPROM=1

sns_inputAnalog_ID=<ID>
sns_inputAnalog_TIMER=<TIMER>
#The resolution of sensor reading, should not be set lower than 10ms
sns_inputAnalog_POLL_PERIOD_MS=20

#Set this parameter to the number of supported sensors
sns_inputAnalog_NUM_SUPPORTED=4

### Config first voltage port ###
# AD channel
sns_inputAnalog0AD=4
# Choose AD factor 
# For a voltage port, factor=5*(R1+R2)/R2 (for def of R1 and R2 see http://en.wikipedia.org/wiki/Voltage_divider)
sns_inputAnalog0Factor=33.3333
# Choose AD scaling
sns_inputAnalog0Scale=10
#Pullup enable port
sns_inputAnalog0Pullup=GPIO_D0
sns_inputAnalog0PullupPCA95xx=0
#GND Reference enable port
sns_inputAnalog0Ref=GPIO_D1
sns_inputAnalog0RefPCA95xx=0


### Config second voltage port ###
# AD channel
sns_inputAnalog1AD=1
# Choose AD factor 
# For a voltage port, factor=5*(R1+R2)/R2 (for def of R1 and R2 see http://en.wikipedia.org/wiki/Voltage_divider)
sns_inputAnalog1Factor=33.3333
# Choose AD scaling
sns_inputAnalog1Scale=10
#Pullup enable port
sns_inputAnalog1Pullup=GPIO_D2
sns_inputAnalog1PullupPCA95xx=0
#GND Reference enable port
sns_inputAnalog1Ref=GPIO_D4
sns_inputAnalog1RefPCA95xx=0


### Config third voltage port ###
# AD channel
sns_inputAnalog2AD=0
# Choose AD factor 
# For a voltage port, factor=5*(R1+R2)/R2 (for def of R1 and R2 see http://en.wikipedia.org/wiki/Voltage_divider)
sns_inputAnalog2Factor=0.002151
# Choose AD scaling
sns_inputAnalog2Scale=10
#Pullup enable port
sns_inputAnalog2Pullup=GPIO_D5
sns_inputAnalog2PullupPCA95xx=0
#GND Reference enable port
sns_inputAnalog2Ref=GPIO_D6
sns_inputAnalog2RefPCA95xx=0


### Config fourth voltage port ###
# AD channel
sns_inputAnalog3AD=2
# Choose AD factor 
# For a voltage port, factor=5*(R1+R2)/R2 (for def of R1 and R2 see http://en.wikipedia.org/wiki/Voltage_divider)
sns_inputAnalog3Factor=0.002151
# Choose AD scaling
sns_inputAnalog3Scale=10
#Pullup enable port
sns_inputAnalog3Pullup=GPIO_D7
sns_inputAnalog3PullupPCA95xx=0
#GND Reference enable port
sns_inputAnalog3Ref=GPIO_B0
sns_inputAnalog3RefPCA95xx=0


#USE_PCA95XX=1


## End section sns_inputAnalog -- Do not edit this line